High Pressure Steam Boiler Evaporated
Capacity:1-20t/h
Rated thermal efficiency: 100-104%
Fixed working pressure: ≤1.6MPa
Applicable fuel:natural gas etc.
Capacity:0.7-14MW
Rated thermal efficiency:96-98%
Fixed working pressure:≤1.25MPa
Applicable fuel:Natural gas, light oil, etc.
Capacity:0.7-2.8Mw
Rated thermal efficiency: 97.2-106%
Fixed working pressure:0.1MPa
Applicable fuel:Natural gas, etc.
Capacity:2.8-7.0Mw
Rated thermal efficiency:≥105.5%
Fixed working pressure:-0.02MPa
Applicable fuel:Natural gas, etc.
Capacity:99Kw
Rated thermal efficiency:97.2-104.4%
Fixed working pressure:1.0MPa
Applicable fuel:Natural gas, etc.
Capacity:0.5-4.0 t/h
Rated thermal efficiency:98%
Fixed working pressure:≤1.25MPa
Applicable fuel:electric energy
The treatment and conditioning of boiler feed water must satisfy three main objectives:. Continuous heat exchange; Corrosion protection; Production of high quality steam; External treatment is the reduction or removal of impurities from water outside the boiler. In general, external treatment is used when the amount of one or more of the feed water impurities is too …Get Price
A boiler or steam generator is a device used to create steam by applying heat energy to water.Although the definitions are somewhat flexible, it can be said that older steam generators were commonly termed boilers and worked at low to medium pressure (7–2,000 kPa or 1–290 psi) but, at pressures above this, it is more usual to speak of a steam generator.Get Price
The low-pressure saturated steam flows up through the matrix, collecting the evaporated compounds. In HD (Fig. 6.5C), the matrix is in direct contact with the boiling water either by floating or by being completely immersed, depending on its density. The boiler is inside the still and agitation may be necessary to prevent agglutination.Get Price
Sep 01, 2014 · Heating the boiler for chemical cleaning using an auxiliary boiler or steam from another unit adds complexity and cost to the cleaning. These high-pressure pumps can produce high purge water Get Price
In a steam boiler system, there are three potentially destructive elements: oxygen, carbon dioxide, and solids. 2.2.2 As the boiler water is heated and changes to steam, free oxygen is released, carbon dioxide is released from the solids, and the solids drop out (precipitate). 2.2.3 As the steam is used in the end process, it cools and condensesGet Price
Sep 15, 2016 · Boiler fuel can include wood chips, pellets, sawdust, or bio-oil. Steam from the boiler is then expanded through a steam turbine, which spins to run a generator and produce electricity. In general, all biomass systems require fuel storage space and some type of fuel handling equipment and controls.Get Price
In a steam boiler system, there are three potentially destructive elements: oxygen, carbon dioxide, and solids. 2.2.2 As the boiler water is heated and changes to steam, free oxygen is released, carbon dioxide is released from the solids, and the solids drop out (precipitate). 2.2.3 As the steam is used in the end process, it cools and condensesGet Price
Superheater, drums, and boiler tube system maximum design pressure, the vendor to specify, but a minimum of 300 kPa (3 bar) above operating pressure is required. Steam drum and boiler tube system maximum design temperature specified on data sheet, superheater design temperature per …Get Price
Sep 26, 2016 · For industrial companies using a boiler for its facility, some type of boiler feed water treatment system is usually necessary to ensure an efficient process and quality steam generation. The most appropriate boiler feed water treatment system will help the facility avoid costly plant downtime, expensive maintenance fees, and boiler failure as a result of scaling, …Get Price
Steam Production From steam tables we can see that the total heat of steam does not vary a great deal as the boiler pressure increase The boiling point (b.p.) increases as the pressure increases Thus the sensible heat increases as the pressure increases, and the latent heat decreases Boiler pressures are expressed in psia, psig, bar, kg/cm2 Get Price
Superheater, drums, and boiler tube system maximum design pressure, the vendor to specify, but a minimum of 300 kPa (3 bar) above operating pressure is required. Steam drum and boiler tube system maximum design temperature specified on data sheet, superheater design temperature per …Get Price
3. A water tube boiler evaporated 5.05 kg of water per second from a feed water temperature of 104.44 °C to steam at 1241.1 kPa and quality of 0.97; weight of coal fuel per second 0.57 kg; higher heating value of coal as fired, 11,800 Btu/lb. Determine the rate of absorption in kJ/s, the boiler horsepower, and the efficiency of steam Get Price
Contaminated boiler and steam systems, as well as systems that operate at over 900 psig, may require a more thorough chemical cleaning. This should be preceded by an alkaline cleaning to prevent oil or grease from interfering with the cleaning process unless a single-stage alkaline/chelant cleaning solution is used.Get Price
keeps the boiler clean. 6. Steam Stop Valve: It regulates the flow of steam supply outside. The steam from the boiler first enters into an ant-priming pipe where most of the water particles associated with steam is removed. 7. Feed Check Valve: The high pressure feed water is supplied to the boiler through this valve.Get Price
Contaminated boiler and steam systems, as well as systems that operate at over 900 psig, may require a more thorough chemical cleaning. This should be preceded by an alkaline cleaning to prevent oil or grease from interfering with the cleaning process unless a single-stage alkaline/chelant cleaning solution is used.Get Price
Boiler feed water Condensate Drinking Treated Fire water High pressure steam Medium pressure steam Low pressure steam Drainage Town gas OILS: Evaporated spinbath Black Canary yellow Brilliant green Floculent solution Black Brilliant green - Lime Smoke grey White Canary yellow Get Price
A kilogram of steam at a higher pressure occupies less volume than at a lower pressure. It follows that, if steam is generated in the boiler at a high pressure and also distributed at a high pressure, the size of the distribution mains will be smaller than that for a low-pressure system for the same heat load. Figure 10.1.2 illustrates this point.Get Price
A kilogram of steam at a higher pressure occupies less volume than at a lower pressure. It follows that, if steam is generated in the boiler at a high pressure and also distributed at a high pressure, the size of the distribution mains will be smaller than that for a low-pressure system for the same heat load. Figure 10.1.2 illustrates this point.Get Price
keeps the boiler clean. 6. Steam Stop Valve: It regulates the flow of steam supply outside. The steam from the boiler first enters into an ant-priming pipe where most of the water particles associated with steam is removed. 7. Feed Check Valve: The high pressure feed water is supplied to the boiler through this valve.Get Price
In order for a high temperature boiler or steam engine to produce superheated water, or steam: All the water has evaporated. A device used to measure the atmospheric pressure is the barometer. True. The pressure changes from 1 atmosphere to 48 atmospheres. If the initial temperature of the gas was 305 K, what was the final temperature?Get Price
Steam Production From steam tables we can see that the total heat of steam does not vary a great deal as the boiler pressure increase The boiling point (b.p.) increases as the pressure increases Thus the sensible heat increases as the pressure increases, and the latent heat decreases Boiler pressures are expressed in psia, psig, bar, kg/cm2 Get Price
Feb 02, 2011 · High pressure liquid enters the boiler from the feed pump (1) and is heated to the saturation temperature (2). Further addition of energy causes evaporation of the liquid until it is fully converted to saturated steam (3). 3-4 Isentropic Expansion. The vapor is expanded in the turbine, thus producing work which may be converted to electricity.Get Price
A boiler or steam generator is a device used to create steam by applying heat energy to water.Although the definitions are somewhat flexible, it can be said that older steam generators were commonly termed boilers and worked at low to medium pressure (7–2,000 kPa or 1–290 psi) but, at pressures above this, it is more usual to speak of a steam generator.Get Price
Boiler feedwater heaters are designed to improve boiler efficiency by extracting heat from streams such as boiler water blowdown and turbine extraction or excess exhaust steam. Feedwater heaters are generally classified as low-pressure (ahead of the deaerator), high-pressure (after the deaerator), or deaerating heaters.Get Price
May 22, 2019 · Steam Turbine. In general, a steam turbine is a rotary heat engine that converts thermal energy contained in the steam to mechanical energy or to electrical energy.In its simplest form, a steam turbine consist of a boiler (steam generator), turbine, condenser, feed pump and a variety of auxiliary devices. Unlike with reciprocating engines, for instance, compression, …Get Price
Boiler feedwater heaters are designed to improve boiler efficiency by extracting heat from streams such as boiler water blowdown and turbine extraction or excess exhaust steam. Feedwater heaters are generally classified as low-pressure (ahead of the deaerator), high-pressure (after the deaerator), or deaerating heaters.Get Price
Sep 02, 2019 · When you hear the term boiler water, this refers to any water that's situated in a boiler or the pumps and piping surrounding the boiler for the main purpose of being evaporated into steam. Boiler water is used in many different industries for such applications as heating, sterilization, and humidification.Get Price
Sep 02, 2019 · When you hear the term boiler water, this refers to any water that's situated in a boiler or the pumps and piping surrounding the boiler for the main purpose of being evaporated into steam. Boiler water is used in many different industries for such applications as heating, sterilization, and humidification.Get Price
The low-pressure saturated steam flows up through the matrix, collecting the evaporated compounds. In HD (Fig. 6.5C), the matrix is in direct contact with the boiling water either by floating or by being completely immersed, depending on its density. The boiler is inside the still and agitation may be necessary to prevent agglutination.Get Price
IDE's low temperature thermal distillation units are capable of producing both drinking and boiler feed water from seawater. They are available in two versions differentiated by the method used for the supply of energy: Multi-Effect Distillation (MED), a low-pressure steam process.Get Price