Natural Gas Atmospheric Pressure Fire Tube Boiler Manufacturers
Capacity:1-20t/h
Rated thermal efficiency: 100-104%
Fixed working pressure: ≤1.6MPa
Applicable fuel:natural gas etc.
Capacity:0.7-14MW
Rated thermal efficiency:96-98%
Fixed working pressure:≤1.25MPa
Applicable fuel:Natural gas, light oil, etc.
Capacity:0.7-2.8Mw
Rated thermal efficiency: 97.2-106%
Fixed working pressure:0.1MPa
Applicable fuel:Natural gas, etc.
Capacity:2.8-7.0Mw
Rated thermal efficiency:≥105.5%
Fixed working pressure:-0.02MPa
Applicable fuel:Natural gas, etc.
Capacity:99Kw
Rated thermal efficiency:97.2-104.4%
Fixed working pressure:1.0MPa
Applicable fuel:Natural gas, etc.
Capacity:0.5-4.0 t/h
Rated thermal efficiency:98%
Fixed working pressure:≤1.25MPa
Applicable fuel:electric energy
Rupture disks are replaced after actuation or periodically as part of preventative maintenance or inspection. These devices are manufactured in accordance with provisions of the ASME Boiler and Pressure Vessel Code (ASME B&PV Code), Section VIII.They are certified by the National Board through a program that tests samples for correct burst pressure and flow resistance.Get Price
Nov 07, 2016 · Absorption chillers can be direct-fired, using natural gas or fuel oil, or indirect-fired. Indirect-fired units may use different sources for heat: hot water or steam from a boiler, steam from district heating, or waste heat in the form of water, air, or other gas.Get Price
• CSA B51 Boiler, Pressure Vessel and Pressure Piping Code • CSA B52 Mechanical Refrigeration Code • CAN/CSA Z184 Gas Pipeline Systems • ASME Boiler & Pressure Vessel Code • ASME B31 Pressure Piping Codes • B31.1 Power Piping • B31.3 Process Piping • B31.4 Liquid Transportation Systems for Hydrocarbons, Liquid PetroleumGet Price
A high pressure watertube boiler (also spelled water-tube and water tube) is a type of boiler in which water circulates in tubes heated externally by the fire. Fuel is burned inside the furnace, creating hot gas which boils water in the steam-generating tubes.In smaller boilers, additional generating tubes are separate in the furnace, while larger utility boilers rely on the water-filled …Get Price
Rupture disks are replaced after actuation or periodically as part of preventative maintenance or inspection. These devices are manufactured in accordance with provisions of the ASME Boiler and Pressure Vessel Code (ASME B&PV Code), Section VIII.They are certified by the National Board through a program that tests samples for correct burst pressure and flow resistance.Get Price
• CSA B51 Boiler, Pressure Vessel and Pressure Piping Code • CSA B52 Mechanical Refrigeration Code • CAN/CSA Z184 Gas Pipeline Systems • ASME Boiler & Pressure Vessel Code • ASME B31 Pressure Piping Codes • B31.1 Power Piping • B31.3 Process Piping • B31.4 Liquid Transportation Systems for Hydrocarbons, Liquid PetroleumGet Price
A non-condensing boiler will not last, because condensate is corrosive. The condition that causes a boiler to condense is reduced flue gas temperature. The point at which condensing will occur, also called the dew point of the products of natural gas (or propane) combustion, is about 130F.Get Price
A high pressure watertube boiler (also spelled water-tube and water tube) is a type of boiler in which water circulates in tubes heated externally by the fire. Fuel is burned inside the furnace, creating hot gas which boils water in the steam-generating tubes.In smaller boilers, additional generating tubes are separate in the furnace, while larger utility boilers rely on the water-filled …Get Price
A non-condensing boiler will not last, because condensate is corrosive. The condition that causes a boiler to condense is reduced flue gas temperature. The point at which condensing will occur, also called the dew point of the products of natural gas (or propane) combustion, is about 130F.Get Price
As a "rule of thumb," 1 ft 3 of natural gas theoretically requires 10 ft 3 of air for complete combustion at 60°F and 14.7 psi under perfect conditions. Of course, this never happens, therefore burner combustion air fans may be sized for 25% excess air, in which case the fan would deliver 12.5 ft 3 of air per 1 ft 3 of natural gas Get Price
As a "rule of thumb," 1 ft 3 of natural gas theoretically requires 10 ft 3 of air for complete combustion at 60°F and 14.7 psi under perfect conditions. Of course, this never happens, therefore burner combustion air fans may be sized for 25% excess air, in which case the fan would deliver 12.5 ft 3 of air per 1 ft 3 of natural gas Get Price
Gas or Oil Fired Integrated Hot Water Boiler. China integrated two-pass wetback fire tube boiler is an ideal choice for all industrial and commercial applications. This kind of boiler provides fuel efficiency that exceeds all four-pass and three pass designs. The boiler's front doors can be opened without removing any burner components or controls.Get Price
According to the circulation of gases: Fire-tube boiler; Water-tube boiler; Fire-tube boiler: Fire tube boilers are those boilers in which hot gases produced by the combination of fuel in the boiler furnace while on their way to chimney pass through a number of tubes (called fuel tubes or smoke tubes) which are immersed in water.Get Price
Dec 01, 2016 · The relationship of gas pressure to gas volume was predetermined by nozzle-calibration tests. The corresponding heat input to the boiler was calculated to be 19,200 to 52,000 Btu/br (5.7 to 15.4 kW)· from the known low heat value of methane (910 Btu/ft 3, or 34 MJ/m 3) and the methane content of the gas (60%). Figure 52.Get Price
Gas or Oil Fired Integrated Hot Water Boiler. China integrated two-pass wetback fire tube boiler is an ideal choice for all industrial and commercial applications. This kind of boiler provides fuel efficiency that exceeds all four-pass and three pass designs. The boiler's front doors can be opened without removing any burner components or controls.Get Price
According to the circulation of gases: Fire-tube boiler; Water-tube boiler; Fire-tube boiler: Fire tube boilers are those boilers in which hot gases produced by the combination of fuel in the boiler furnace while on their way to chimney pass through a number of tubes (called fuel tubes or smoke tubes) which are immersed in water.Get Price